Notice: Undefined offset: 9 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 10 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 11 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 12 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 13 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 14 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 15 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 16 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 17 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 18 in /home/www/www.solarvps.com/html/include/functions.php on line 947

Notice: Undefined offset: 19 in /home/www/www.solarvps.com/html/include/functions.php on line 947
Solar VPS :: Data Facilities
Overview
The 100 Delawanna Avenue data facility is located in Clifton, New Jersey and is owned and operated by Fortress Integrated Technologies. Solar VPS operates under a unique partnership with this facility allowing us priority access, customized rack and network design and 24 hour remote hands support. All servers are housed in high end Middle Atlantic data cabinets with locking front and rear doors. Racks are powered by dual 30 amp circuits and 18 port Baytech remote power control units. Rack cooling is handled by top mounted 10 inch 825 CFM high speed fans and forced air from the 18 inch raised floor.
Power
The data center provides redundant power systems with an Inline power backup using Liebert UPS system and an onsite Caterpillar generator with 4 days of standby fuel. In the event of a power outage, the power management system starts the generator within seconds and transfers power to the UPS for charging. The Liebert UPS, controls and constantly monitors the quality of power so that all equipment receives 120-volt power, all the time. Moreover, the UPS and generators are tested weekly to avoid power disruptions.
Cooling Systems
The data center is safeguarded by redundant indoor cooling systems that are kept at an optimal temperature. The cooling systems offer an accurate and reliable control of humidity, airflow, and room temperature that improves the working conditions for the susceptible electronic equipment. The data center has been set in a place with 7,500 sq ft of raised flooring with 8, 20-ton AC units.
Cabinets
The data center offers high tech key locked cabinets that are fully secure and as per an individual's requirements. The cabinets come with both front and back lock and their bases are attached to the floor. All the cabinets allow for increased air circulation and their side panels can be detached to enhance expandability.
Security
The data center has a high level of security, guarded by 24/7/365 digital surveillance of the facilty. The closed circuit cameras throughout the data center monitor both the interior and exterior facilities around-the-clock. In addition, keycard locks are located on all the paths to sensitive areas and biometric palm scans restrict access to authorized personnel only.
Gallery
Overview
The 110 Meadowlands Parkway data facility is located in Secaucus, New Jersey and is owned and operated by Iinterserver, Inc. Solar VPS operates under a unique partnership with this facility allowing us priority access, customized rack and network design and 24 hour remote hands support. Racks are powered by triple 20 amp circuits and 8 port Baytech remote power control units. Open rack units allow for ample cooling and cable management. The data center floor sits atop 18 inch raised flooring.
Power
The data center provides redundant power systems with an Inline power backup using Powerware UPS systems and multiple onsite 1 megawatt diesel generators with ample standby fuel. In the event of a power outage, the power management system starts the generator within seconds and transfers power to the UPS for charging. The Powerware UPS, controls and constantly monitors the quality of power so that all equipment receives 120-volt power, all the time. Moreover, the UPS and generators are tested weekly to avoid power disruptions.
Cooling Systems
The data center is safeguarded by redundant indoor cooling systems that are kept at an optimal temperature. The cooling systems offer an accurate and reliable control of humidity, airflow, and room temperature that improves the working conditions for the susceptible electronic equipment. The data center has been set in a place with 6,000 sq ft of raised flooring with 3, 20-ton AC units.
Security
The data center has a high level of security, protected by ADT security badge entry on all the paths to sensitive areas which restricts access to authorized personnel only.
Gallery
Overview
The BlueSquare House is the original site for the BlueSquare data center concept. Opened in August 2006, at 10,000 sq.ft. in size, it provides up to 16 Amps per cabinet location with N+1 redundancy at all times.
Power
The data center provides redundant power systems with an Inline power backup using Powerware UPS systems and multiple 2 megawatt diesel generators with ample standby fuel. In the event of a power outage, the power management system starts the generator within seconds and transfers power to the UPS for charging. The Powerware UPS, controls and constantly monitors the quality of power so that all equipment receives 230-volt power, all the time. Moreover, the UPS and generators are tested weekly to avoid power disruptions.
Cooling Systems
The data center is safeguarded by redundant indoor cooling systems that are kept at an optimal 22°C +/- 2°C temperature. The cooling systems offer an accurate and reliable control of humidity, airflow, and room temperature that improves the working conditions for the susceptible electronic equipment. The data center has been constructed with 10,000 sq ft of 430mm raised flooring and an N+1 Airedale Air Handling system.
Security
The data center has a high level of security, protected by 24x7 secure entry via swipe card system with 6-layer entry which restricts access to authorized personnel only. The data center was built inside its own secure compound, with 3-meter fencing and electric entry, including anti-tailgate systems.
Gallery
Data Facility Fast Facts
55,000 sq. ft. facility
7,500 sq. ft. of raised floor
(7) 20-ton Liebert Data Air AC units
500 Smoke and Heat Detectors
Security badge entry/exit on all doors
(3) 225KVA Liebert UPS units
1-megawatt caterpillar generator
6000 gallons of emergency standby fuel
24x7 Network and facility monitoring software
100% Redundant Cisco Network
Data Facility Fast Facts
8,000 sq. ft. facility
6,500 sq. ft. datacenter space
(3) HVAC units totaling 60 tons
Overhead AC ducts for cooling distribution
Pre-action dry pipe sprinkler system
ADT security badge entry
2000 amps of 480v input power
(2) 500KVA Powerware UPS units
1-megawatt generator (2000 gallon tank)
Data Facility Fast Facts
10,000 sq.ft total size
1.5 megawatt on-site substation
Diverse power feeds to substation
Broadcrown 2 megawatt generator connected via ATS systems
N+1 PowerWave UPS system
N+1 Airedale Air Handling system
~22°C +/- 2°C data floor temperature
16 Amp feed per equipment rack
24x7 secure entry via swipe card system, with 6-layer entry
Data center located inside its own secure compound, with 3-meter fencing and electric entry, including anti-tailgate systems
Onsite NOC engineers available 24x7 for remote hands service
430mm raised heavy duty flooring